| Storage Networking Support |
| Platform/Connectivity |
SNC 5100 (2 Gb Fibre Channel) or SNC 3000 (1 Gb Fibre Channel) |
| Management Services |
End-to-end path verification, error recovery, drive performance optimization, SAN security (Scalar Firewall Manager), serverless backup (Data Mover Module) |
| Reliability |
| Drive Hard Error Rate |
Less than 1 in 1017 bits |
| Tape Shelf Life |
30 years minimum (at 20°C, 40% RH) |
| Library MCBF |
Greater than 2,000,000 |
| Drive MTBF |
Greater than 200,000 power-on hours |
| Power |
2N power for all systems and drives |
| MTTR |
30 minutes |
| Library Control Ports |
Dual, redundant ports are standard |
| Diagnostics |
SNMP traps reported through RMU or Scalar DLC. Built-in self-test, store/restore past events, fault isolation assistance, self-initiating configuration and calibration; email alert |
| Module Upgrade |
Any storage module may be added in two hours; customer installable drive and slot upgrade |
| Operation |
| Cartridge Change |
Up to 450 per hour |
| Drive Interface |
LTO and Native Fibre: SCSI-2 LVD; integrated FC interface optional for all; TS1120: SCSI-2, SNC or Native FC LVD or HVD |
| Library Interface |
SCSI-2 LVD or HVD; integrated FC interface optional |
| Inventory Speed |
100 slots in 20 seconds* |
| Configuration |
Auto-discovery and auto-calibration for installed or added components (modules, drives, magazines, tapes, etc.) |
| Import/Export |
Up to 72 (LTO/TS1120 positions) in removable magazines |
| Environmental |
| Power |
208-240VAC; 20 amp per cabinet |
| Temperature |
16 to 32°C operating |
| Humidity |
15 to 75% non-condensing operating |
| Compliance and Certification |
| Safety |
EN 60950 with deviations |
| Emissions |
CISPR 22/EN 55022 Class A |
| Immunity |
EN 55024 |
| International |
CE, FCC, ICES, cTUVus, TUV/GS |