| Operation |
| Drive Interface |
SCSI-2 LVD; integrated FC interface option; Native FC interface option |
| Library Interface |
SCSI-2 LVD; Native FC interface |
| Inventory Speed |
100 slots in 20 seconds |
| Configuration |
Auto-discovery and auto-calibration for installed/added components (modules, tapes, drives, magazines, etc.) |
| Import/Export |
Up to 192 (LTO), 160 (SDLT) positions in removable magazines |
| Environmental |
| Electrical |
115-230 VAC, 2-16 kVA |
| Temperature |
15 to 32°C operating |
| Humidity |
10 to 90% non-condensing operating |
| Reliability |
| Library MCBF |
Greater than 2,000,000 |
| Library MTTR |
20 minutes |
| Power |
Optional 2N power for all systems and drives |
| Diagnostics |
Embedded monitoring of major subsystems, self-diagnostic procedures, and policy-based e-mail and pager alerts to system administrators and ADIC Global Services |
| Module Upgrade |
Any storage module may be added in two hours; customer-installable components include drives, fans, power supplies, slot upgrades |
| Physical |
| Control Module (H x W x D) |
Dimensions: 77.4" x 24.2" x 37.4" (1,965mm x 615mm x 950mm) |
| Expansion Module (H x W x D) |
77.4" x 23.6" x 37.4" (1,965mm x 600mm x 950mm) |
| Compliance and Certification |
| Safety |
UL-1950 ITE, CSA950, EN 60950 |
| Emissions |
FCC #47 CFR, Part 15, Class A, CSA C108.9M, EN 55022, Class A |
| Immunity |
IEC (1000-4-2,-3,-4) |
| International |
CE |